MethyPrecise® Probe-Based Methylation Detection qPCR Master Mix (2× Methy-qPCR Mix) (JSR-E-206, JSR-E-207)
Product item number | Packaging Specifications | Price |
JSR-E-206 | 100 times | 580 |
JSR-E-207 | 500 times | 2680 |
Keywords
Category
Product Description
FAQ
Product Information
Related Documents
Jianshi Bio MethyPrecise® Probe-Based Methylation Detection qPCR Premix (JSR-E-206 Series)
Product Overview
This product is the MethyPrecise® probe‑based methylation detection qPCR master mix (2× Methy‑qPCR Mix, catalog no. JSR‑E‑206 series), specifically optimized for DNA methylation analysis. It is formulated with a genetically engineered hot‑start enzyme and a proprietary buffer, enhancing bisulfite‑template compatibility, GC‑content tolerance (25%–70%), uracil resistance, and 3′‑end mismatch discrimination, while delivering exceptional sensitivity and specificity. The master mix is supplied as a ready‑to‑use 2× formulation; users need only add primers, probes, and template. It comes with two ROX reference dye options—high and low—and is compatible with mainstream qPCR instruments. Amplification curves exhibit excellent linearity, quantitative accuracy, and high reproducibility, making it suitable for assays such as methylation site detection and SNP genotyping. We recommend using this product in conjunction with the JSR‑530 Bisulfite Modification Kit. Available in 100‑ and 500‑reaction formats, store at −25°C to −15°C; intended solely for research use.
Product Features
- Specifically optimized for methylation detection, this product combines a genetically engineered hot-start enzyme with a dedicated buffer to significantly enhance multiplex target‑specific detection performance in methylation‑based assays.
- Compatible with a broad GC content range, it is suitable for templates with 25%–70% GC content, covering the methylation detection needs of diverse genomic regions.
- Designed for robust tolerance, it exhibits excellent compatibility with sulfite conversion products and uracil‑modified templates, thereby minimizing template‑inhibition effects.
- It exhibits strong recognition of mismatched bases at the 3′ end, enabling precise differentiation between methylated and unmethylated sites and achieving high detection specificity.
- High sensitivity with low‑copy detection; excellent multiplex target‑detection sensitivity; even low‑abundance methylated templates can be stably detected.
- Excellent amplification performance, with a highly linear amplification curve, accurate quantification of the target gene, and high reproducibility of experimental results.
- 2× ready-to-use pre-mix; simply add primers, probes, and template to streamline the workflow and minimize pipetting errors.
- Comes with dual-concentration ROX reference dye, available in high and low concentrations, and compatible with mainstream qPCR instruments from various brands—no additional purchase required.
- The reaction system is highly flexible and customizable, with a 5–25 μL reaction volume that can be scaled proportionally to accommodate varying experimental throughput and sample‑size requirements.
- Strict quality control ensures a one-year warranty; the product delivers stable and reliable performance and is intended solely for research and experimental use, not for clinical diagnostics.
Performance Verification Data
Using a methylation‑qPCR assay, amplification was performed at two genomic loci, A and B, with each template analyzed in duplicate. The results were compared with those obtained using a competing product of the same type, Y, to evaluate the assay’s amplification efficiency, linearity, and detection sensitivity.
Comparison of Amplification Performance of Gene A
Competitor Y of the same type
Jianshi JSR-E-206
| Brand | Conversion input quantity | Cq 1 | Cq 2 | Average Cq (Avg) |
|---|---|---|---|---|
| Competitor Y of the same type | 1ng | 36.10 | 36.95 | 36.53 |
| 10ng | 33.34 | 34.09 | 33.71 | |
| 20ng | 32.54 | 32.27 | 32.41 | |
| 100ng | 29.46 | 29.54 | 29.50 | |
| 200ng | 28.36 | 28.69 | 28.53 | |
| 300ng | 27.95 | 27.63 | 27.79 | |
| 500ng | 27.10 | 27.01 | 27.05 | |
| Jianshi JSR-E-206 | 1ng | 36.02 | 39.18 | 37.60 |
| 10ng | 32.72 | 32.41 | 32.56 | |
| 20ng | 31.85 | 32.02 | 31.94 | |
| 100ng | 28.91 | 28.76 | 28.83 | |
| 200ng | 27.90 | 27.86 | 27.88 | |
| 300ng | 27.17 | 27.37 | 27.27 | |
| 500ng | 26.31 | 26.36 | 26.34 |
Comparison of B Gene Amplification Performance
Competitor Y of the same type
Jianshi JSR-E-206
| Brand | Conversion input quantity | Cq 1 | Cq 2 | Average Cq (Avg) |
|---|---|---|---|---|
| Competitor Y of the same type | 1ng | 37.09 | 35.68 | 36.39 |
| 10ng | 32.73 | 33.28 | 33.01 | |
| 20ng | 31.53 | 31.31 | 31.42 | |
| 100ng | 28.69 | 28.85 | 28.77 | |
| 200ng | 27.89 | 27.70 | 27.79 | |
| 300ng | 27.01 | 26.91 | 26.96 | |
| 500ng | 26.52 | 26.17 | 26.35 | |
| Jianshi JSR-E-206 | 1ng | 36.32 | 36.39 | 36.36 |
| 10ng | 32.38 | 31.62 | 32.00 | |
| 20ng | 30.74 | 30.89 | 30.81 | |
| 100ng | 27.81 | 27.74 | 27.77 | |
| 200ng | 26.61 | 26.85 | 26.73 | |
| 300ng | 26.11 | 25.30 | 25.71 | |
| 500ng | 25.30 | 25.26 | 25.28 |
Jianshi Bio MethyPrecise® Probe-Based Methylation Detection qPCR Premix
2×Methy-qPCR Mix: Specialized Reagent for Methylation Quantitative Detection – Frequently Asked Questions
Core Performance Features
- Methylation-specific : Hot-start enzyme + optimized buffer, suitable for methylation detection assays
- Highly tolerant and widely compatible : Sulfite-resistant, compatible with templates containing 25–70% GC content
- High sensitivity and high accuracy : Strong capability for detecting low-copy targets, excellent amplification linearity, and precise quantification.
- Easy to operate : 2× pre-mix system; only primers, probes, and template need to be added.
Item Number, Specifications, and Composition
- JSR-E-206 : 100 reactions, 1 mL pre-mix
- JSR-E-207 : 500 reactions, 5 × 1 mL aliquots of premix
- Matching dye : Comes with two reference dyes, 50× ROX High and Low.
- Storage conditions : Store frozen and protected from light at -25 to -15°C.
Applicable experimental scenarios
- Methylation detection : Quantitative detection of DNA methylation sites
- Genotyping : SNP Detection and Allele Typing
- Conversion sample : Sulfite-converted DNA sample analysis
- Low-copy detection : Sensitive detection of trace methylated templates
High-Frequency FAQs for Methylation qPCR Master Mix
This product is a 2× probe-based qPCR master mix specifically optimized for DNA methylation detection. It employs an engineered hot-start enzyme and a proprietary buffer system, significantly enhancing the assay performance for methylated samples.
1. Formulation Optimization: Composed of a genetically engineered hot-start enzyme and an optimized reaction buffer, specifically tailored for methylation detection applications.
2. Tolerance and compatibility: Exhibits strong sulfite tolerance, is compatible with templates spanning 25–70% GC content, and demonstrates robust uracil tolerance as well as the ability to recognize 3′-terminal mismatched bases.
3. Excellent performance: Multi‑target sensitivity and specificity, as well as the ability to detect low‑copy‑number targets, have been significantly enhanced; amplification curves exhibit outstanding linearity, and quantitative accuracy for target genes is high.
4. Convenient operation: A 2× pre-mix system requires only the addition of primers, probes, and template during use, significantly reducing pipetting steps and minimizing experimental errors.
Two reaction‑scale options are available: a pre‑mix plus a dual‑concentration ROX reference dye kit, eliminating the need to purchase additional reagents.
1. Item number and specifications:
• JSR-E-206: 100 reactions specification, including 1 mL of 2× pre-mix;
• JSR-E-207: 500 reactions, including 5 × 1 mL of 2× pre-mix, for convenient aliquoting and use;
2. Core components:
• 2×Methy-qPCR Mix: Pre-mixed with hot-start DNA polymerase, dNTPs, an optimized buffer system, and more;
• 50×ROX High: High-concentration reference dye;
• 50×ROX Low: Low-concentration reference dye.
Standardized storage and handling are critical to ensuring enzyme activity and amplification stability.
1. Storage conditions: Store frozen at -25°C to -15°C, protected from light; a one-year quality guarantee is provided from the date of sale.
2. Pre-use preparation: After removal, place on ice to thaw; once completely thawed, gently invert to mix, then briefly centrifuge before use.
3. Instrument‑use requirements: Prepare the reaction mixture, securely cap the tubes, and briefly centrifuge them to remove air bubbles that could interfere with fluorescence signal acquisition.
4. Post-use handling: Immediately replace the cap and store at −20°C to prevent prolonged exposure of the reagent to room temperature.
A standard 20 μL reaction system with clearly defined component ratios, which can be adjusted as needed within a specified range.
1. Standard 20 μL reaction system:
• 2×Methy-qPCR Mix: 10 μL
• Forward Primer (10 μM): 0.4 μL
• Reverse Primer (10 μM): 0.4 μL
• Probe (10 μM): 0.4 μL
• Template DNA: Add as needed (recommended 2 μL)
• 50×ROX (Low/High): 0.4 μL
• ddH₂O: bring to 20 μL
2. System Adjustment: The reaction volume can be scaled proportionally within the range of 5–25 μL; volumes exceeding 50 μL are not recommended.
3. Concentration Optimization: The final concentrations of primers and probes can be adjusted within the range of 0.1–1 μM to achieve optimal amplification performance.
ROX is used for fluorescence signal baseline correction and must be selected to match the specific qPCR instrument model to ensure quantitative accuracy.
1. ROX High : Compatible with Applied Biosystems® models 5700, 7000, 7300, 7700, 7900HT, StepOne™, StepOnePlus™, and others;
2. ROX Low : Compatible with Applied Biosystems® 7500, ViiA™ 7, QuantStudio™ 12K Flex, Agilent Mx3000P™, Mx3005P™, Mx4000™, and other models;
3. No ROX required : Compatible with Rotor-Gene™, Opticon™, Chromo4™, LightCycler® series, Bio-Rad CFX96, Illumina Eco™, and other models.
Optimized for methylated samples, with broad GC tolerance and high bisulfite resistance, it is compatible with a wide range of post‑conversion DNA samples.
1. Applicable templates: DNA samples after sulfite conversion, methylated standards, plasmid templates, genomic DNA, etc.;
2. GC compatibility range: Compatible with templates having 25% to 70% GC content; targets with varying GC contents can all be stably amplified.
3. Tolerance characteristics: Exhibits excellent uracil tolerance, strong recognition of 3′-terminal mismatched bases, and is well suited to the base‑specific properties of DNA following bisulfite conversion.
4. Template recommendation: For methylation analysis, we recommend using our company’s JSR530 kit for bisulfite conversion.
The standard two-step amplification protocol allows for flexible adjustment of parameters based on the template’s GC content and the primers’ Tm values.
1. Standard qPCR protocol (two-step method):
• Pre-denaturation: 95°C for 30 seconds, 1 cycle;
• Amplification cycles: 95°C denaturation for 10 seconds, followed by 60°C annealing/extension for 30 seconds with fluorescence acquisition, for a total of 35–45 cycles.
2. Parameter Optimization:
• Denaturation: For high-GC templates, the denaturation time can be extended to 3–5 minutes to ensure complete template denaturation.
• Annealing temperature: Adjust according to the primer/probe Tm value, with a range of 50–65°C; for initial experiments, a preliminary run at 60°C is recommended.
• Number of cycles: Typically 35–40 cycles; for low-copy-number samples, the cycle number may be increased to 45.
Abnormal amplification curves are often caused by issues such as instrument calibration, template concentration, air bubbles, or baseline settings; these can be systematically investigated and resolved.
1. The curve is not smooth. The reasons are system uncalibration, template concentration too low, and incorrect ROX selection.
Solution: Recalibrate the instrument’s fluorescence system, increase the template concentration, and verify that ROX is compatible with the instrument.
2. Curve breakage/decline The reasons are excessively high template concentration and an inappropriate baseline selection range.
Solution: Reduce the template concentration, reset the baseline range, and avoid regions with fluorescence fluctuations.
3. A sudden drop in individual curves The reason is that bubbles in the reaction tube interfere with fluorescence detection.
Solution: Before loading the sample, briefly centrifuge the PCR tube to remove air bubbles from the bottom and walls.
No amplification or elevated Ct values can stem from various factors, including the template, reagents, reaction conditions, and primers; systematically troubleshooting each step will help quickly pinpoint the issue.
1. No amplification curve Common causes and solutions:
• Insufficient cycle number: It is recommended to set ≥40 cycles;
• Signal acquisition not configured: Verify that fluorescence detection is enabled during the annealing‑extension step of the two‑step protocol.
• Primer degradation: Prимер integrity is assessed by PAGE electrophoresis; if degradation is detected, the primer is resynthesized.
• Template concentration too low/degradation: Increase the template loading amount, or prepare the template anew.
2. High Ct value Common causes and solutions:
• Low amplification efficiency: Optimize reaction conditions, try a three-step amplification protocol, or redesign the primers.
• Low template concentration: reduce template dilution and increase the amount loaded.
• Overly long PCR products: It is recommended to keep the amplicon length between 80 and 150 bp.
• Presence of PCR inhibitors: Increase the template dilution factor, or re-purify the template.
Three common types of experimental issues correspond to different optimization strategies:
1. A clear amplification was observed in the negative control. :
Cause: Contamination of the reaction system and non-specific primer design.
Solution: Replace the reagents, water, and primers; perform all procedures within a clean bench to minimize aerosol contamination; and redesign the primers to enhance specificity.
2. The standard curve exhibits poor linearity. :
Causes: pipetting errors, degradation of standards, and excessively high template concentrations.
Solution: Increase the template dilution factor and the sample volume, re‑prepare the standards, and optimize the gradient concentration range.
3. The experiment has poor reproducibility. :
Reasons: inconsistent sample volumes and excessively low template concentrations.
Solution: Use a pipette with higher precision, reduce the template dilution factor, or increase the aliquot volume; pre‑mix common reagents and then aliquot.
Related Products
Order Consultation: Hu Manager
Order Consultation: An Manager
End-user Scientific Research Customer Order Consultation
Technical Consultation: Bai Technical
Customer Service
Douyin
WeChat Video Account
Kuaishou
Contact Us
Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province