16-Channel Automated Nucleic Acid Extraction Instrument (Model B) (TI16-B)
Product Name | Product item number· | Packaging Specifications | Price |
16-Channel Automated Nucleic Acid Extractor - B | TI16-B | Taiwan | 17500 |
Keywords
Category
Product Description
FAQ
Product Information
Related Documents
Jianshi Bio 16-Channel Automated Nucleic Acid Extraction Instrument (TI16-B)
Product Overview
This product is a 16-channel automated nucleic acid extraction instrument (Model B, catalog number TI16‑B), based on magnetic bead‑based nucleic acid purification technology. It can automatically extract DNA and RNA from various sample types. Each run supports a flexible throughput of 1 to 16 samples, is compatible with 96‑well deep‑well plates, and handles reaction volumes ranging from 30 μL to 1000 μL. Magnetic bead recovery exceeds 98%, and inter‑well variability (CV) is less than 5%. Featuring an open‑platform programming system, it allows users to customize protocols and is compatible with reagent kits from multiple manufacturers. Optional features include a heating module, UV disinfection, power‑off protection, and safety‑door interlocks. The instrument supports multiple operating modes, with programs that can be imported and exported via USB flash drive, and comes preloaded with over 500 preset protocols. With its compact footprint and low‑noise operation, it is designed for benchtop placement and is widely used in research, genomics, food safety, and other fields; intended solely for research use only (RUO).
Product Features
- 16-channel flexible throughput; a single run can process 1 to 16 samples, compatible with 96‑well deep‑well plates, and handles volumes from 30 to 1,000 μL, covering mainstream extraction requirements.
- Open‑architecture software that allows users to freely create, edit, and delete protocols, and is compatible with nucleic acid extraction kits based on magnetic bead technology from multiple manufacturers.
- Temperature-controlled heating module, supporting pre-heating for lysis and elution; temperature adjustable from room temperature to 120°C, enhancing nucleic acid release and elution efficiency.
- Power‑off memory protection: upon resuming power after an unexpected outage, the system prompts whether to continue the program, thereby preventing sample loss and experiment interruption.
- Multiple safety protection mechanisms: the machine automatically pauses when the safety door is opened and resumes operation upon closure; a missing magnetic rod sleeve triggers an alert to safeguard the magnetic rod.
- Four operating modes—scan‑code operation, list‑based operation, quick‑access operation, and run‑on‑demand viewing—are available for intuitive and efficient operation.
- Program import and export via USB flash drive, enabling synchronization across multiple instruments; built-in library of over 500 preset programs; ready to use out of the box with mainstream reagent kits.
- Equipped with a built-in UV disinfection system, the chamber undergoes UV sterilization after experiments to prevent cross-contamination between samples from different batches.
- End-to-end operational logging captures and automatically archives runtime information, facilitating experiment traceability and quality management.
- The magnetic rods and rod sleeves are independently controlled, with operating noise below 55 dB; the equipment features low wear and long service life, making it well-suited for quiet laboratory environments.
- Dual-language (Chinese–English) touch interface, smooth Android system operation, supports USB and Wi‑Fi interfaces, and enables software firmware upgrades.
Technical Specifications of the 16-Channel Nucleic Acid Extractor
| Specification Category | Item number | Product Name | Core Parameters |
|---|---|---|---|
| 16-Channel Nucleic Acid Extractor, Model B | TI16-B | 16-Channel Automated Nucleic Acid Extractor – B, Fully Automated Nucleic Acid Purification System Using the Magnetic Bead Method | Processing throughput: 1–16 samples per run; processing volume: 30 μL–1000 μL; magnetic bead recovery rate: >98%; inter‑well CV: <5%; heating range: selectable from room temperature to 120°C; interface: bilingual (Chinese–English) Android touchscreen; noise level: <55 dB; power supply: AC 110/220 V, 200 W. |
Jianshi Bio TI16-B Nucleic Acid Extraction Instrument
16-Channel Magnetic Bead-Based Automated Nucleic Acid Extraction Instrument – FAQs on High-Frequency Issues
Core Performance Features
- 16-channel flux : Flexible handling of samples 1–16, compatible with 96‑well deep‑well plates
- Open Programming : The program is customizable and can be configured to work with reagent kits from multiple manufacturers.
- Precise temperature control : Pre-heating for pyrolysis elution, adjustable from room temperature to 120°C
- Multi-layered protection : Safety door interlock, power-off protection, magnetic rod protection
Product Specifications and Parameters
- Item number :TI16-B
- Processing volume : 30 μL ~ 1000 μL
- Magnetic bead recovery rate : >98%, purification sensitivity >95%
- Inter-hole variation : CV < 5%, with good extraction uniformity
Operation and Functionality
- Four operating modes : Scan QR code / Directly / View / Quick Run
- Ultraviolet disinfection : Built-in UV lamp to prevent cross-contamination between batches.
- Program Management : USB flash drive import and export, supports software upgrades
- Low-noise operation Independent magnetic rod control, noise < 55 dB
TI16-B Nucleic Acid Extractor – High-Frequency FAQs
This instrument is a 16-channel magnetic-bead-based automated nucleic acid extraction system, compatible with a wide range of magnetic-bead–based reagent kits, and delivers stable, consistent extraction performance.
1. Sample throughput: Supports simultaneous processing of 1 to 16 samples and is compatible with standard 96‑well deep‑well plates.
2. Processing volume: The single-well processing volume ranges from 30 μL to 1000 μL and can be flexibly adjusted according to experimental requirements.
3. Extraction performance: magnetic bead recovery rate > 98%, purification sensitivity > 95%, and inter-well variability (CV) < 5%.
4. Temperature Control Range: An optional heating module is available, with a temperature adjustment range from room temperature to 120°C, supporting pre-heating for lysis and elution steps.
Unboxing and installation must be performed strictly in the prescribed sequence; failure to remove the securing devices can result in direct damage to the instrument.
1. Unboxing and Inspection: Verify the contents against the packing list, checking the main unit, power cord, user manual, and other accessories. If any damage or missing items are found, contact after-sales service immediately.
2. Key operating procedure: Before connecting the power, be sure to open the chamber door, remove the internal securing screws and the transport foam, then close the front door securely before powering on.
3. Installation requirements: Do not place the instrument on a soft cushion; maintain a clearance of at least 25 cm between the rear of the instrument and the wall to ensure adequate ventilation and heat dissipation; install in a dry indoor environment free from corrosive substances and strong magnetic fields.
It features four built-in operating modes, catering to diverse application scenarios such as routine experiments, batch testing, and debugging/validation.
1. Scan to Run : By scanning the kit barcode with a barcode scanner, the corresponding program is automatically invoked, making it ideal for standardized, high-throughput experiments.
2. Run directly : Select the program from the program list and click Run to start it; this is suitable for routine experiments with fixed workflows.
3. View Running : Allows you to view the program’s detailed execution steps and supports starting execution from a specified step, making it ideal for experimental debugging and resuming work mid‑process.
4. Quick Run Add frequently used programs to the quick-launch list for one-click, rapid startup, boosting the efficiency of high-frequency experimental tasks.
The system is open and programmable, supporting full‑process customization, and allows simultaneous program synchronization across multiple instruments via a USB flash drive.
1. Editing Functions: Supports creating, editing, deleting, and renaming protocols; allows users to customize parameters for each step, including well positions, wait times, mixing durations, magnetic capture times, liquid volumes, temperatures, and mixing speeds.
2. Import/Export: Program files can be exported to or imported from a USB flash drive using the password 789, enabling batch synchronization of program settings across multiple instruments.
3. Software Upgrade: Supports system software and firmware updates via USB flash drive, enabling continuous optimization of instrument performance.
The instrument is equipped with a comprehensive power‑off protection system to prevent experimental samples from being ruined by sudden power interruptions.
1. Recovery Prompt: When power is restored after an unexpected outage, the system will automatically display a prompt asking whether to resume the previous program.
2. Two options: Select “Yes” to resume the program from the step it was at before the power outage; select “No” to re‑select the program after system initialization.
3. Data Storage: Real-time recording of operating status to minimize the impact of power outages on experiments.
It features a built-in UV disinfection function, which effectively prevents cross-contamination between samples from different batches.
1. Operating procedure: On the main interface, select “UV Disinfection,” set the disinfection duration, and tap “Start” to initiate the countdown; once disinfection is complete, the UV lamp will automatically turn off.
2. Safety Interlock: During the disinfection process, if the front safety door is opened, the UV lamp automatically shuts off and the timer pauses; once the door is closed, the timer resumes, ensuring operator safety.
3. Precautions: Do not look directly at the ultraviolet light; the acrylic panel of the front safety door is equipped with UV‑filtering properties. During the disinfection process, other function buttons are temporarily disabled.
Proper cleaning and maintenance can extend the instrument’s service life and ensure extraction stability.
1. Routine cleaning: After the experiment is completed, disconnect the power supply, wipe the interior of the experimental chamber with cotton swabs soaked in 75% ethanol, allow it to air dry, and then activate UV disinfection for at least 30 minutes.
2. Regular maintenance: Avoid cleaning with strong alkalis or high-concentration alcohol; keep the experimental chamber dry; if not used for an extended period, cover it with a dust cover and run it once every 30 days.
3. Prohibited Operations: Cleaning is strictly prohibited during instrument operation; do not use high-concentration organic solvents to wipe the instrument’s surface.
Multiple safety protection mechanisms ensure comprehensive operational safety and stable equipment performance.
1. Safety door interlock: During operation, opening the front safety door immediately triggers an automatic program pause; closing the safety door resumes the program automatically.
2. Magnetic Rod Protection: The system automatically issues a warning if the magnetic rod sleeve is not properly installed, preventing operation without the sleeve and thereby reducing corrosion of the magnetic rod and extending the lifespan of consumables.
3. High-Temperature Protection: The heating module becomes extremely hot during operation; the system is marked with warning signs, and touching it is prohibited to prevent burns.
Common simple malfunctions can be troubleshooted using the following methods; if the issue cannot be resolved, please contact after-sales technical support.
1. The startup screen does not display. : Check that the power cord is securely plugged in and that the power fuse is intact; reinsert it firmly or replace it with a fuse of the same rating.
2. The operation is accompanied by abnormal noises. : Verify that the transport‑fixing long screws have been removed, that the mixing sleeve is properly seated, and that the 96‑well deep‑well plate is placed evenly.
3. Abnormal magnetic rod movement : Click the “Stop” button to reset; if the issue persists after resetting, please contact customer service.
4. System crash and loss of control : After disconnecting the power and restarting the instrument, if the issue persists, please contact technical support.
We offer a one-year free warranty and lifetime maintenance services to ensure the instrument’s long-term stable operation.
1. Free Warranty: Within 12 months from the date of shipment, any malfunctions caused by technical or material defects will be repaired free of charge, provided the product has been used in accordance with the operating instructions, is not subject to damage due to misuse, and has not been repaired by unauthorized personnel.
2. Lifetime Maintenance: After the warranty period expires, we provide lifetime maintenance services, charging only the cost of replacement parts.
3. Warranty Conditions: Operate strictly in accordance with the instruction manual, use the specified power supply, and do not disassemble or repair the device without authorization.
Related Products
Order Consultation: Hu Manager
Order Consultation: An Manager
End-user Scientific Research Customer Order Consultation
Technical Consultation: Bai Technical
Customer Service
Douyin
WeChat Video Account
Kuaishou
Contact Us
Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province
WhatsApp: 86 18640171737
Leave a Message
If you are interested in our products, please leave your phone number.
Consult Now →Product Subscription
Subscribe to us to stay informed about product updates and special offers
WhatsApp:
mzhao@jianshibio.com:
WeChat:
8601058235289: