Conventional Coomassie Brilliant Blue Staining and Destaining Solution (JSR-DY1005)
Keywords
Category
Product Description
FAQ
Product Information
Related Documents
Jianshi Bio Standard Coomassie Brilliant Blue Staining and Destaining Solution (JSR-DY1005)
Product Overview
This product is a standard Coomassie Brilliant Blue staining and destaining solution (Catalog No. JSR-DY1005-500), specifically designed for polyacrylamide gel protein electrophoresis. It features an optimized methanol-free formulation that delivers consistent destaining performance and a clear background. Two protocols are available: the conventional method offers high sensitivity and stable results, ideal for precise protein analysis; the rapid method, combined with heating, enables quick band visualization and shortens the experimental workflow. The procedure is straightforward, with absorbent paper optionally used to accelerate destaining, and multiple gel‑preservation options—including storage in water, glycerol, or dry‑gel preparation—provided. Packaged in a convenient 500 mL size, it can be stored at room temperature, and the staining solution is reusable. This product is suitable for a wide range of protein electrophoresis staining and destaining experiments and is intended solely for research use.
Product Features
- A methanol-free optimized formulation delivers stable and reliable decolorization, ensures thorough background removal, and reduces the toxicity and volatility risks associated with organic solvents.
- The dual‑decolorization method is compatible: the conventional approach offers high sensitivity and stable results, while the rapid method provides fast band visualization upon heating, catering to diverse experimental efficiency requirements.
- Accelerated decolorization design: during the decolorization process, absorbent paper is added to adsorb dyes, effectively shortening the decolorization time and enhancing experimental efficiency.
- A variety of gel‑preservation protocols are available, supporting storage in water, 20% glycerol, or dry‑gel preparation, thereby accommodating diverse downstream applications and storage requirements.
- The staining solution is reusable and can be reused up to approximately three times, thereby reducing experimental consumable costs.
- Stored at room temperature, with no need for a cold chain; convenient for storage and transportation, and simplifies laboratory inventory management.
- 500 mL large‑volume packaging, compatible with standard laboratory batch protein electrophoresis experiments, meeting high‑throughput application requirements.
- Low operational complexity—no complicated preparation required; simply dispense as needed. Comes with a complete step-by-step guide, making it easy for beginners to get started.
- A set of frequently asked questions clarifies the advantages and disadvantages of the two methods, as well as key considerations, facilitating rapid troubleshooting of experimental issues.
- Rigorous molecular biology‑grade quality control ensures consistent performance across batches and excellent reproducibility of experimental results; intended for research use only.
Jianshi Bio Standard Coomassie Brilliant Blue Staining and Destaining Solution
SDS-PAGE Protein Gel Staining and Destaining Reagent – Frequently Asked Questions
Core Performance Features
- Methanol-free formula : Reliable decolorization performance, with low volatility for enhanced safety
- Dual decolorization mode : Conventional method with high sensitivity + rapid method with quick-read strip
- Easy to operate Ready to use right out of the box, supports absorbent paper for accelerated decolorization.
- Multiple save options : Comprehensive coverage of water immersion, glycerol preservation, and dry gel preparation
Product Specification Information
- Item number : JSR-DY1005-500
- Specifications : 500 mL standard size
- Storage Conditions Store at room temperature, sealed and protected from light.
- Staining solution reuse : The staining solution can be reused approximately 3 times.
Applicable experimental scenarios
- SDS-PAGE : Staining of polyacrylamide gel protein electrophoresis
- Protein assay : Qualitative and quantitative analysis of total protein
- Purity Identification : Recombinant protein and antibody purity assay
- Save Results : Gel imaging and result archiving and storage
Frequently Asked Questions on Coomassie Brilliant Blue Staining and Destaining Solutions
It employs a methanol-free, optimized formulation that, while ensuring reliable decolorization performance, significantly enhances both safety of use and environmental friendliness.
1. Key features: The formulation is methanol-free, delivering a clean background with clear bands and stable, reliable destaining performance.
2. Safety Advantages: Prevents laboratory air pollution caused by methanol volatilization, reduces the risk of flammability and explosiveness, and eliminates the need for specialized ventilation and protective measures.
3. Operational Advantages: The reagents have a mild odor and low irritancy to operators, providing a more comfortable experience during prolonged use.
4. Storage advantages: Can be stored at room temperature without the need for specialized low-temperature storage, with excellent reagent stability.
The two decolorization modes are tailored to different experimental needs and can be selected based on the urgency of the timeline and the required sensitivity:
1. Conventional staining and destaining method : Room-temperature shaking incubation for decolorization; advantages include higher detection sensitivity, uniform band visualization, and stable, reliable results; the drawback is that it is relatively time-consuming.
2. Rapid staining and destaining method Microwave-assisted staining and destaining can reveal bands in 5–10 minutes; its advantages include rapid processing and a shortened experimental timeline. Its drawbacks are slightly lower detection sensitivity compared with conventional methods, and gel integrity may be compromised during boiling at low concentrations, so precautions against bumping are necessary.
3. Precautions: Rapid heating can accelerate the volatilization of acetic acid; therefore, it is recommended to perform this procedure in a fume hood. For gels with concentrations below 10%, avoid boiling whenever possible to prevent gel fragmentation.
Various techniques can effectively shorten the destaining time while ensuring high-quality band visualization.
1. Absorbent paper–accelerated method: During the destaining process, place a piece of absorbent paper in the destaining solution; free dye will adsorb onto the paper, significantly speeding up background destaining.
2. Liquid‑exchange enhancement method: During the destaining process, replace the fresh destaining solution 1–2 times to rapidly reduce the background dye concentration and improve destaining efficiency.
3. Temperature-assisted method: Raising the temperature of the decolorizing solution to an appropriate range (room temperature to 37°C) and combining it with shaking on a shaker can accelerate the decolorization rate.
4. Precautions: Prolonged destaining may cause protein bands to fade or weak bands to disappear; monitor the destaining process in real time and stop as soon as the desired results are achieved.
Depending on the desired storage duration, you can choose an appropriate preservation method to effectively prevent gel swelling and band broadening.
1. Short-term storage: After destaining, immerse the gel in pure water for short-term storage, suitable for subsequent imaging and documentation.
2. Anti‑swelling storage: To prevent the gel from swelling and deforming due to water absorption, store it in an aqueous solution containing 20% glycerol to maintain its shape and band clarity.
3. Long-term preservation: For results that require long-term archiving, the samples can be prepared as dry gels for permanent storage of protein band profiles.
Based on observed phenomena, targeted troubleshooting of operational steps can be conducted to optimize dyeing and decolorization results.
1. The blue background cannot be completely removed. Common causes include insufficient decolorization time, inadequate volume of decolorizing solution, and failure to replace the decolorizing solution with fresh solution in a timely manner. Solutions: extend the decolorization time, replenish the decolorizing solution to ensure complete immersion of the gel, replace the decolorizing solution with fresh solution, and add absorbent paper to accelerate the removal of background dye.
2. The protein band is too faint. Common causes include excessive decolorization time, insufficient staining time, and a low protein loading amount; solutions: control the decolorization time while monitoring in real time, appropriately extend the staining time, and increase the sample loading volume.
3. Band-like blurring and diffusion Common causes include mismatched gel concentration, over‑running during electrophoresis, and excessive decolorization temperature. Solutions: select a gel concentration appropriate for the protein’s molecular weight, optimize electrophoresis parameters, and perform decolorization at room temperature to avoid high temperatures.
Related Products
Order Consultation: Hu Manager
Order Consultation: An Manager
End-user Scientific Research Customer Order Consultation
Technical Consultation: Bai Technical
Customer Service
Douyin
WeChat Video Account
Kuaishou
Contact Us
Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province
WhatsApp: 86 18640171737
Leave a Message
If you are interested in our products, please leave your phone number.
Consult Now →Product Subscription
Subscribe to us to stay informed about product updates and special offers
WhatsApp:
mzhao@jianshibio.com:
WeChat:
8601058235289: