DL5000 DNA Molecular Weight Standard (TM1007)
Product Name | Item number | Packaging Specifications | Price |
DL5000 DNA Molecular Weight Standard | TM1007-50 | 300 µL | Request for quotation |
DL5000 DNA Molecular Weight Standard | TM1007-100 | 300 µL × 2 | Request for quotation |
DL5000 DNA Molecular Weight Standard | TM1007-200 | 300 µL × 4 | Request for quotation |
Keywords
plasmid DNA miniprep extraction kit oem
Category
Product Description
FAQ
Product Information
Related Documents
Jianshi Bio DL5000 DNA Molecular Weight Standard (TM1007)
Product Overview
This product is the DL5000 DNA Molecular Weight Standard (DNA Marker, catalog number TM1007 series), prepared as a mixture of individually synthesized PCR products. It comprises nine DNA ladder fragments: 5,000 bp, 3,000 bp, 2,000 bp, 1,500 bp, 1,000 bp, 750 bp, 500 bp, 250 bp, and 100 bp, covering a broad range from 100 to 5,000 bp and suitable for analyzing large‑fragment nucleic acids. The product is pre‑mixed with 1× Loading Buffer, making it a ready‑to‑use reagent; simply load 3–6 μL onto the gel for electrophoresis, yielding clear, well‑defined bands. The stock solution has a concentration of approximately 91 ng/μL; at a standard loading volume of 6 μL, the 1,500‑bp and 500‑bp bands each contain about 100 ng, while the remaining fragments each contain roughly 50 ng. Two brightly labeled reference bands facilitate accurate molecular‑weight estimation. The product is available in three packaging sizes. For short‑term storage, keep refrigerated at 4°C away from light (avoid repeated freeze–thaw cycles); for long‑term storage, store sealed at −20°C. Each batch undergoes rigorous nucleic‑acid quality testing, and a one‑year quality warranty is provided from the date of sale. It is suitable for molecular‑weight calibration in agarose gel electrophoresis of double‑stranded DNA, including PCR products, plasmid restriction digests, and long‑fragment amplification products, and is intended solely for research use (RUO).
Product Features
- Nine‑segment, full‑coverage gradient strips can accommodate up to 5,000 bp of large fragments, balancing short‑fragment amplification with the analysis of plasmid restriction‑enzyme digestion products, thus broadening their range of applications.
- Dual‑highlighted reference bands ensure doubled loading capacity for 1500‑bp and 500‑bp markers, providing clear references across both high‑ and low‑molecular‑weight ranges for more efficient molecular‑weight determination.
- Pre-mix with 1× loading buffer; simply load the sample directly out of the box, eliminating the need to prepare and dilute the buffer and streamlining the pre-electrophoresis workflow.
- The stock solution maintains a stable concentration of 91 ng/μL, with uniform and consistent band intensity across batches, and exhibits excellent electrophoresis reproducibility.
- Flexibly compatible with various sample wells: For standard loading, use 3–6 μL; adhere to the guideline of adding 1 μL per 1 mm well width, and slightly increase the load volume for wider wells.
- A universal nucleic acid electrophoresis system, compatible with 1–2% agarose gels; a recommended electrophoresis voltage of 4–10 V/cm; and suitable for standard laboratory electrophoresis equipment.
- Standardized low-temperature storage protocol: short-term storage at 4°C and long-term storage at −20°C; seal the vial immediately after use to prevent reagent degradation and loss of potency.
- Comprehensive, batch‑by‑batch nucleic acid testing ensures product stability, and an official one‑year full‑scope quality warranty is provided.
- Complementary electrophoresis optimization tips: regularly replace the electrophoresis buffer and use fresh gels to minimize artifacts such as smearing, spurious bands, and band blurring.
- Comes with a standard electrophoresis band reference map, allowing direct comparison with sample electrophoresis images for rapid and accurate determination of DNA fragment molecular weights.
DL5000 DNA Marker Technical Specifications (All Sizes)
| Specification Category | Item number | Product Name | Packaging Specifications |
|---|---|---|---|
| DL5000 DNA Marker, 300 μL per vial | TM1007-50 | DL5000 DNA molecular weight standard, pre-mixed with 1× Loading Buffer, ready to use. | 300 μL/vial |
| DL5000 DNA Marker, 300 μL, pack of two | TM1007-100 | DL5000 DNA molecular weight standard, pre-mixed with 1× Loading Buffer, ready to use. | 300 μL × 2 vials |
| DL5000 DNA Marker, 300 μL, pack of four | TM1007-200 | DL5000 DNA molecular weight standard, pre-mixed with 1× Loading Buffer, ready to use. | 300 μL × 4 vials |
Jianshi Bio DL5000 DNA Molecular Weight Standard TM1007 Full Series
9‑Lane Ready‑to‑Use DNA Electrophoresis Marker with Ultra‑Large Fragments – FAQ Handbook for Common Issues
Core Nucleic Acid Parameters
- Fragment band : 9 standard bands at 5000/3000/2000/1500/1000/750/500/250/100 bp
- Stock solution concentration : Approximately 91 ng/μL; pre-mix with 1× Loading Buffer for immediate use.
- Sample loading capacity : 6 μL loaded; 1500 bp/500 bp approximately 100 ng, with the remaining bands at 50 ng.
- Applicable Experiment : Long-fragment PCR verification, plasmid restriction digestion, and vector construction by electrophoresis
Full range of item numbers and specifications
- TM1007-50 : Single 300 µL basic mini-packaging
- TM1007-100 : 2 × 300 µL Medium-Sized Laboratory Kit
- TM1007-200 : 4 × 300 µL high-throughput bulk packaging
- Warranty Standards : 12-month full warranty from the date of purchase
Electrophoresis and Storage Guidelines
- Recommended gel : 1%–2% agarose gel system
- Electrophoresis voltage : 4–10 V/cm gel length
- Short-term storage : Store temporarily at 4°C away from light; do not store for extended periods.
- Long-term storage : Store at -20°C, protected from light; strictly prohibit repeated freeze-thaw cycles.
DL5000 DNA Marker TM1007 Series – Frequently Asked Questions
This ultra‑high‑resolution marker panel comprises nine DNA fragments, with a maximum coverage of 5,000 bp. It features dual bands at 1,500 bp and 500 bp, offering enhanced loading capacity and improved resolution for long‑fragment electrophoresis.
1. Full-length fragments: 5,000 bp, 3,000 bp, 2,000 bp, 1,500 bp, 1,000 bp, 750 bp, 500 bp, 250 bp, 100 bp;
2. Nucleic acid loading: The two bands at 1500 bp and 500 bp each correspond to approximately 100 ng, while the remaining seven molecular-weight bands all correspond to 50 ng.
3. The accompanying electrophoresis schematic clearly resolves 5,000- and 3,000-bp super-large DNA fragments, making it suitable for determining the molecular weights of plasmids and long‑fragment amplification products.
The entire product line offers three standardized packaging options, tailored to meet the monthly consumption needs of different laboratories:
1. TM1007-50: Individually packaged, with a single‑tube volume of 300 µL;
2. TM1007-100: The kit contains two units, each with a volume of 300 µL, for a total volume of 600 µL.
3. TM1007-200: The kit contains 4 tips, each with a volume of 300 µL, for a total volume of 1200 µL.
The product is a ready-to-use, pre‑formulated marker. The stock solution is pre‑mixed with 1× Loading Buffer, eliminating the need to prepare buffer yourself; simply open the cap and load directly.
1. Directly pipette 3–6 μL into the gel well to complete the sample loading.
2. The buffer contains an electrophoresis indicator, enabling intuitive monitoring of nucleic acid migration distance and preventing excessive loss of very large DNA fragments during gel electrophoresis.
3. Eliminates the buffer preparation step, reducing the risk of exogenous nucleic acid contamination in long‑fragment samples.
1. The overall nucleic acid concentration of the stock solution is approximately 91 ng/μL, with a homogeneous system free of precipitates and localized concentration or stratification.
2. Recommended sample loading volume range: 3 μL to 6 μL;
3. For low‑copy, long‑fragment PCR products, 6 μL can be used to enhance band intensity; for high‑concentration plasmid restriction‑enzyme digest products, 3 μL is sufficient for clear visualization.
Ultra‑high molecular weight DNA is highly sensitive to temperature fluctuations; it is advisable to employ separate short‑term and long‑term storage protocols, as repeated freeze–thaw cycles can directly degrade long‑fragment nucleic acids.
1. Short-term temporary storage (to be used within 1 month): Store in a sealed container, protected from light, at 4°C.
2. Long-term storage (more than 1 month): Store at −20°C, protected from light.
1. Official warranty period: A full one-year (12-month) quality guarantee is provided from the date of purchase.
2. Warranty Coverage: Under compliant low-temperature storage conditions, requests for after-sales service may be submitted in cases of band loss, nucleic acid degradation, or insufficient concentration.
3. Not covered under warranty: Reagent degradation and failure resulting from storage at elevated temperatures, repeated freeze–thaw cycles, or prolonged exposure to air after opening the container.
1. Gel concentration compatibility: 1%–2% agarose gels; a 1% low‑concentration gel is suitable for separating ultra‑large fragments of 5,000/3,000/2,000 bp, while a 2% gel is ideal for the precise resolution of small fragments ranging from 100 to 1,000 bp.
2. Electrophoresis voltage control standard: 4–10 V/cm between the gel’s two electrodes;
3. In low-concentration gels, large DNA fragments migrate at a slower pace with well‑defined, smooth bands; in high-concentration gels, small fragments achieve higher resolution, but such gels are not suitable for separating fragments longer than 5,000 bp.
1. Basic conversion standard: For each 1 mm of well width, load 1 μL of DL5000 Marker.
2. For standard electrophoresis gels, a well width of 3–4 mm is recommended, and a typical loading volume of 3–4 μL is sufficient to meet imaging requirements.
3. For preparative-scale gels with large pore sizes, the sample volume may be increased proportionally to the pore width; however, the total volume loaded in a single run should not exceed 10 μL to prevent sample overflow and cross-contamination of adjacent lanes.
1. Prolonged exposure of the sample to air after opening the cap: nucleic acids volatilize and oxidize, the buffer pH shifts, and the intensity of all bands decreases markedly.
2. Repeated freeze–thaw cycles of reagents: long‑fragment DNA strands degrade, and the prominent 5,000‑bp and 3,000‑bp bands disappear entirely.
3. Reusing expired electrophoresis buffer or long‑stored, aged gels: bands become compressed and overlapped, with severe smearing;
4. Long-term storage at room temperature: Nucleic acids degrade rapidly, rendering the entire reagent vial completely ineffective.
After thorough staining with a nucleic acid dye, the gel can clearly resolve nine bands corresponding to different molecular weights when placed under a UV imaging system, enabling straightforward and accurate determination of very large DNA fragments.
1. Standard observation procedure: electrophoresis completed → staining with nucleic acid dye → imaging and documentation using a UV transilluminator or gel imaging system;
2. Common causes of band smearing and large‑fragment loss: ① Repeated reuse of electrophoresis buffer leading to loss of efficacy; ② Gel concentration too high, resulting in poor resolution of very large fragments; ③ Insufficient sample volume; ④ Repeated freeze–thaw cycles of reagents causing degradation of long DNA fragments; ⑤ Excessively high electrophoresis voltage, leading to gel heating and diffusion.
Related Products
Order Consultation: Hu Manager
Order Consultation: An Manager
End-user Scientific Research Customer Order Consultation
Technical Consultation: Bai Technical
Customer Service
Douyin
WeChat Video Account
Kuaishou
Contact Us
Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province
WhatsApp: 86 18640171737
Leave a Message
If you are interested in our products, please leave your phone number.
Consult Now →Product Subscription
Subscribe to us to stay informed about product updates and special offers
WhatsApp:
mzhao@jianshibio.com:
WeChat:
8601058235289: