DL2000 Plus DNA Molecular Weight Standard (TM1006)
Product Name | Item number | Packaging Specifications | Price |
DL2000 Plus DNA Molecular Weight Standard | TM1006-50 | 300 µL | Request for quotation |
DL2000 Plus DNA Molecular Weight Standard | TM1006-100 | 300 µL × 2 | Request for quotation |
DL2000 Plus DNA Molecular Weight Standard | TM1006-200 | 300 µL × 4 | Request for quotation |
Keywords
Category
Product Description
FAQ
Product Information
Related Documents
Jianshi Bio DL2000 Plus DNA Molecular Weight Standard (TM1006)
Product Overview
This product is the DL2000 Plus DNA Molecular Weight Standard (DNA Marker, catalog number TM1006 series), prepared as a mixture of individually synthesized PCR products. It comprises seven DNA ladder bands: 2000 bp, 1500 bp, 1000 bp, 750 bp, 500 bp, 250 bp, and 100 bp, with an added 1500‑bp band, providing finer resolution across the 100–2000 bp range. The product is pre‑mixed with 1× Loading Buffer, making it a ready‑to‑use reagent; simply load 3–6 μL for electrophoresis, yielding clear, well‑defined bands. The stock solution has a concentration of approximately 66 ng/μL; at a standard loading volume of 6 μL, the 750‑bp band corresponds to about 100 ng, while each of the other bands contains roughly 50 ng, with the intermediate bands exhibiting enhanced brightness for easy interpretation. The product is available in three packaging sizes. For short‑term storage, keep refrigerated at 4°C away from light (avoid repeated freeze–thaw cycles); for long‑term storage, store sealed at −20°C. Each batch undergoes rigorous nucleic acid quality testing, and a one‑year quality warranty is provided from the date of sale. It is suitable for molecular weight calibration in agarose gel electrophoresis of double‑stranded DNA, including PCR products and plasmid restriction digests, and is intended solely for research use (RUO).
Product Features
- Seven gradient‑based, finely tuned fragment sizes are provided, with an additional 1500‑bp band that fills the gap in the standard DL2000 range, delivering enhanced resolution for nucleic acid fragments between 100 and 2000 bp.
- Pre-mix 1× sample buffer—ready-to-use and pre‑formulated, eliminating the need to prepare the buffer and streamlining pre‑electrophoresis procedures.
- Differentiated band‑loading design doubles the yield of the 750‑bp band and enhances its brightness, enabling rapid alignment with the central reference ladder for more intuitive molecular‑weight determination.
- The stock solution maintains a stable concentration of 66 ng/μL, with uniform band intensity across batches and excellent electrophoresis reproducibility.
- Flexibly compatible with various gel wells: For standard 3–6 μL sample loading, follow the guideline of adding 1 μL per 1 mm of well width; for wider wells, the sample volume may be increased accordingly.
- A universal nucleic acid electrophoresis system, compatible with 1–2% agarose gels, recommends an electrophoresis voltage of 4–10 V/cm, and is suitable for standard laboratory electrophoresis equipment.
- Standardized low-temperature storage protocol: store at 4°C for short-term use and at −20°C for long-term preservation; immediately reseal the vial after use to prevent degradation and loss of potency.
- Comprehensive nucleic acid-specific quality inspections are conducted on every batch prior to shipment, and a one-year warranty is provided from the date of sale; experimental data are stable and reliable.
- Supporting electrophoresis optimization tips: regularly replace the electrophoresis buffer and use freshly prepared gels to avoid abnormal results such as smearing, spurious bands, and band blurring.
- Comes with a standard electrophoresis band reference map, allowing direct comparison with sample electrophoresis images for rapid and accurate determination of DNA fragment molecular weights.
DL2000 Plus DNA Marker Technical Specifications (All Formats)
| Specification Category | Item number | Product Name | Packaging Specifications |
|---|---|---|---|
| DL2000 Plus DNA Marker, 300 μL per vial | TM1006-50 | DL2000 Plus DNA Molecular Weight Standard, pre-mixed with 1× Loading Buffer, ready to use. | 300 μL/vial |
| DL2000 Plus DNA Marker, 300 μL, pack of two | TM1006-100 | DL2000 Plus DNA Molecular Weight Standard, pre-mixed with 1× Loading Buffer, ready to use. | 300 μL × 2 vials |
| DL2000 Plus DNA Marker, 300 μL, pack of four | TM1006-200 | DL2000 Plus DNA Molecular Weight Standard, pre-mixed with 1× Loading Buffer, ready to use. | 300 μL × 4 vials |
Jianshi Bio DL2000 Plus DNA Molecular Weight Standard TM1006, Full Series
Upgraded 7‑Band Nucleic Acid Electrophoresis Marker – Ready‑to‑Use Reagent; High‑Frequency Issues FAQ Manual
Core Nucleic Acid Parameters
- Fragment band : 2000/1500/1000/750/500/250/100 bp, 7 standard bands
- Original solution concentration : Approximately 66 ng/μL; pre-mix with 1× Loading Buffer for immediate use.
- Sample loading capacity : 6 μL loaded; the 750-bp band corresponds to approximately 100 ng, while the other bands correspond to 50 ng.
- Applicable Experiment : Precise identification of PCR products, distinguishing fragments between 1,000 and 2,000 bp.
Full range of item numbers and specifications
- TM1006-50 : Single 300 µL basic mini-packaging
- TM1006-100 : 2 × 300 µL medium-sized laboratory kit
- TM1006-200 : 4 × 300 µL high-throughput bulk packaging
- Warranty Standards : 12-month full warranty from the date of purchase
Electrophoresis and Storage Guidelines
- Recommended gel : 1%–2% agarose gel system
- Electrophoresis voltage : 4–10 V/cm gel length
- Short-term storage : Store temporarily at 4°C away from light; do not store for extended periods.
- Long-term storage : Store at -20°C, protected from light; strictly prohibit repeated freeze-thaw cycles.
DL2000 Plus DNA Marker TM1006 Series – Frequently Asked Questions
This upgraded Marker contains seven DNA fragments and features a newly added 1,500-bp band. Its ability to resolve large DNA fragments outperforms that of the standard DL2000, and at a 6-μL loading volume, the bands exhibit uniform brightness in the gel image.
1. Full fragments: 2000 bp, 1500 bp, 1000 bp, 750 bp, 500 bp, 250 bp, 100 bp;
2. Nucleic acid loading: the 750 bp band is approximately 100 ng, while the remaining six bands of different molecular weights are each 50 ng.
3. The accompanying electrophoresis schematic allows for the clear differentiation of adjacent large DNA fragments, addressing the challenge of resolving products in the 1,000–2,000 bp range.
The entire product line offers three standardized packaging options, tailored to meet the monthly usage requirements of different laboratories:
1. TM1006-50: Individually packaged single unit, with a volume of 300 µL per unit;
2. TM1006-100: The kit contains 2 units, each with a volume of 300 µL, for a total kit volume of 600 µL.
3. TM1006-200: The kit contains 4 tips, each with a volume of 300 µL, for a total kit volume of 1200 µL.
The product is a ready-to-use, pre‑formulated marker; the stock solution is pre‑mixed with 1× Loading Buffer, eliminating the need to prepare buffer solutions yourself—simply open the cap and use.
1. Directly pipette 3–6 μL into the gel well to load the sample;
2. The buffer contains an electrophoresis indicator, allowing for intuitive monitoring of nucleic acid migration distance and preventing over‑running.
3. Eliminates the buffer preparation step, reducing the risk of exogenous nucleic acid contamination.
1. The overall nucleic acid concentration of the stock solution is approximately 66 ng/μL, with a homogeneous formulation free of precipitates and localized concentrations.
2. Recommended sample loading volume range: 3 μL to 6 μL;
3. For low‑copy,微量 PCR products, 6 μL can be used to enhance band visibility; for high‑concentration amplification products, 3 μL is sufficient for clear imaging.
Nucleic acid molecular weight standards are sensitive to temperature fluctuations; two distinct storage protocols—short-term and long-term—are recommended, as repeated freeze–thaw cycles will directly render the reagents ineffective.
1. Short-term temporary storage (to be used within 1 month): Store in a sealed container, protected from light, at 4°C.
2. Long-term storage (more than 1 month): Store at −20°C, protected from light.
1. Official warranty period: A full one-year (12-month) quality guarantee is provided from the date of purchase.
2. Warranty Coverage: Under compliant low-temperature storage conditions, claims for after-sales service may be submitted in cases of band loss, nucleic acid degradation, or insufficient concentration.
3. Not covered under warranty: Damage to reagents caused by storage at elevated temperatures, repeated freeze–thaw cycles, or prolonged exposure to air after opening the container.
1. Gel concentration compatibility: 1%–2% agarose gels; a 1% gel is suitable for separating large DNA fragments of 2000/1500/1000 bp, while a 2% gel is ideal for the precise resolution of small fragments ranging from 100 to 750 bp.
2. Electrophoresis voltage control standard: 4–10 V/cm between the gel’s two electrodes;
3. In low-concentration gels, large DNA fragments migrate slowly and produce well‑defined bands; in high-concentration gels, small fragments achieve higher resolution.
1. Basic conversion standard: For each 1 mm of well width, load 1 μL of DL2000 Plus Marker.
2. The standard electrophoresis gel well width is 3–4 mm, and a typical sample volume of 3–4 μL is sufficient.
3. For preparative-scale columns with large pore sizes, the sample volume may be increased proportionally to the pore width; however, the total volume per injection should not exceed 10 μL to prevent sample overflow and cross-contamination of adjacent lanes.
1. Prolonged exposure of the sample to air after opening the cap: nucleic acids volatilize and oxidize, the buffer pH shifts, and the intensity of all bands decreases markedly.
2. Repeated freeze–thaw cycles of reagents: DNA strands degrade, and low‑molecular‑weight bands at 100/250 bp disappear entirely.
3. Reusing expired electrophoresis buffer or long‑stored, aged gels: bands become compressed and overlapped, with severe smearing;
4. Long-term storage at room temperature: Nucleic acids degrade rapidly, rendering the entire reagent vial completely ineffective.
After thorough staining with a nucleic acid dye, the gel can clearly resolve seven bands corresponding to different molecular weights when placed under a UV imaging system, enabling intuitive and accurate determination of molecular weights.
1. Standard observation procedure: electrophoresis is completed → nucleic acid dye–mediated staining → imaging and documentation using a UV transilluminator or gel imaging system;
2. Common causes of band smearing: ① Repeated reuse of electrophoresis buffer leading to loss of efficacy; ② Gel concentration mismatched with the target fragment; ③ Insufficient sample volume; ④ Repeated freeze–thaw cycles causing nucleic acid degradation; ⑤ Excessively high electrophoresis voltage resulting in gel overheating.
Related Products
Order Consultation: Hu Manager
Order Consultation: An Manager
End-user Scientific Research Customer Order Consultation
Technical Consultation: Bai Technical
Customer Service
Douyin
WeChat Video Account
Kuaishou
Contact Us
Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province
WhatsApp: 86 18640171737
Leave a Message
If you are interested in our products, please leave your phone number.
Consult Now →Product Subscription
Subscribe to us to stay informed about product updates and special offers
WhatsApp:
mzhao@jianshibio.com:
WeChat:
8601058235289: