  • Fluorometer1 荧光计(1784599412828).png
  • Fluorometer1 荧光计3(1784599412641).png
  • Fluorometer1 荧光计2(1784599412839).png

Fluorometer (TIQB0001-3)

Item number

Product Name

Introduction

Price

TIQB0001

Fluorometer

With a single sample, this instrument can measure DNA, RNA, and proteins, requiring only 1–20 μL to deliver precise concentration measurements. It offers rapid operation and accurate results, significantly reducing sample consumption and experimental time. This device is particularly well suited for low‑concentration nucleic acid and protein assays in research laboratories, with broad applications including DNA quantification during NGS library construction, RNA quantification, and nucleic acid concentration determination in PCR experiments, thereby providing reliable data to support experimental workflows.

16250

TIQB0002

Fluorometer

TIQB0002 is an eight-sample assay for DNA and protein analysis.

32500

TIQB0003

Fluorometer

TIQB0003 is an eight-sample assay for measuring DNA, RNA, and proteins.

48750


Keywords



Product Description

FAQ

Product Information

Related Documents

Jianshi Bio TIQB0001 Microfluorescence Quantitative Analyzer (Fluorometer)

Product Overview

The TIQB0001 micro‑fluorometer is a benchtop, high‑precision fluorescence detection instrument specifically designed for the quantitative analysis of trace amounts of nucleic acids, proteins, and fluorescent dyes. It features a stable UV excitation source and a highly sensitive photodetection module, supporting four major assay modes—DNA, RNA, total protein, and fluorescent probes—and can detect samples as low as the pg level without requiring large reaction volumes, enabling accurate quantification with only minute sample quantities. The device is equipped with a high‑resolution color capacitive touchscreen, preloaded with multiple standard calibration curves, and includes one‑click self‑diagnostics that automatically perform blank correction, standard curve fitting, and sample reading. Its fully enclosed, light‑shielded measurement chamber eliminates ambient light interference, ensuring excellent data reproducibility. With a compact, lightweight design that minimizes bench space, it supports USB‑based local data export, storage, and printing, and incorporates a comprehensive quality‑control program that automatically flags outlier values. This instrument is suitable for molecular laboratories, disease control centers, pharmaceutical R&D facilities, and third‑party testing organizations, and is widely used for quality control of nucleic acid extraction, protein concentration determination, and quantitative analysis of fluorescent probes. Operation is straightforward, requiring no complex setup; it can be quickly mastered by a single user and is intended solely for research use (RUO), not for clinical in‑vitro diagnostic applications.

Product Features

  • Ultra-high detection sensitivity, with a pg-level limit of detection for trace nucleic acids; quantitative analysis can be performed using minimal sample volumes, significantly conserving precious experimental specimens.
  • Integrated multi‑mode detection, supporting quantitative analysis of four sample types—double‑stranded DNA, single‑stranded RNA, total protein, and fluorescent dyes—enabling versatile, multipurpose use in a single instrument.
  • A closed, fully light‑proof detection chamber isolates the sample from external stray light, eliminating environmental‑light‑induced data bias and yielding low CV values.
  • 7-inch HD capacitive touchscreen, graphical user interface, built-in multiple pre-set standard curves, and support for custom curve saving and recall.
  • Fully automated testing workflow: with a single click, initiate blank zeroing, standard calibration, and sample measurement—eliminating the need for manual step-by-step operations and minimizing human error.
  • Stable, long-life UV-excited light source with a long service life, slow degradation rate, and consistently reliable long-term measurement results.
  • Wide linear detection range; samples spanning high and low concentrations require no serial dilution; the linear range encompasses multiple orders of magnitude, making it suitable for both high- and low-abundance samples.
  • Built-in comprehensive data management system; local storage of up to one thousand test records; USB interface for exporting data in Excel format, facilitating the archiving of experimental records.
  • Built-in automated quality-control judgment algorithm; values outside the acceptable range are automatically highlighted in red to facilitate rapid identification of abnormal samples.
  • Compact, desktop‑style lightweight housing with a small footprint; can be installed inside a fume hood or clean bench and is compatible with various laboratory layouts.
  • Compatible with the standard test kits and fully compatible with all Jianshi nucleic acid and protein fluorescence quantitative reagents.
  • Multi-layered safety protection design: the light source automatically shuts off when the cover is opened, preventing direct UV exposure and protecting operators.
  • Designed for low-noise operation, it enables continuous batch analysis without environmental interference, making it ideal for high-throughput sample screening.

Technical Specifications Details

Parameter Classification Parameter Item Detailed Technical Specifications
Basic Device Information Product item number TIQB0001
Operation Screen 7-inch color capacitive touchscreen
Overall dimensions 310mm×220mm×185mm
Net weight of the entire machine 3.2kg
Optical detection performance Excitation light source Long-life UV LED excitation light source
Limit of detection Trace amounts of nucleic acids at the pg level can be stably detected.
Detection linear range Covers five orders of magnitude, with no dilution required for both high and low concentrations.
Coefficient of variation (CV) test ≤2.5%
Supported detection types dsDNA / ssRNA / total protein / fluorescent dye
Software Data Functionality Standard curve Built-in preset curves, with support for custom curve storage.
Data storage This device can store ≥1,000 sets of test data.
Data Export Export experimental report in Excel format via USB interface
Safety and Environment Cavity Protection Automatic shut-off of the UV light source upon opening the cover.
Work environment Temperature: 10–40°C; Humidity: 20%–85%, no condensation.
Scope of Use For research use only (RUO); not for clinical diagnostic use.
Compatible accessories Compatible consumables 0.2 ml/0.5 ml micro PCR tubes, standard fluorescence detection tubes
Compatible reagents Compatible with the entire Jianshi series of fluorescent quantitative assay kits.

Jianshi Bio TIQB0001 Microfluorescence Quantitative Analyzer

Nucleic Acid and Protein Microfluorescence Detection Equipment FAQ Manual

Core Detection Performance

  • PG-level detection limit Precise quantification of trace samples
  • Four-mode detection DNA/RNA/Protein/Fluorescent Dyes
  • Low CV value The coefficient of variation is ≤2.5%.
  • Light-protected cavity Eliminate ambient light interference

Software Data Functionality

  • 7-inch touchscreen Visualized, Easy Operation
  • Curve Customization Multiple standard curve storage
  • Thousands of storage sets This device retains experimental data.
  • USB Export Excel Standardized Report

Usage and Compatibility

  • Open the cover and disconnect the power. Ultraviolet Safety Interlock Protection
  • Compatible with microcentrifuge tubes 0.2/0.5 ml PCR tube
  • Compatible reagents Jianshi Fluorescent Quantitative Kit
  • RUO only Specialized equipment for scientific research and experimentation

TIQB0001 Fluorescence Detector – High-Frequency FAQ

1: What is the lowest detectable nucleic acid concentration with TIQB0001, and how reproducible is the detection of trace‑low‑abundance samples?

The instrument’s detection limit can reach the pg level, enabling stable detection of extremely low‑abundance nucleic acid samples, with a coefficient of variation (CV) of ≤2.5%.

The instrument features a fully enclosed, light‑shielded detection chamber that completely eliminates external stray light interference. For low‑concentration, precious samples, no gradient dilution is required, and repeated measurements exhibit minimal variability, making it ideal for the precise quantification of trace‑amount extraction products.

2: What types of samples does the instrument support, and do protein samples require special pre‑processing?

It features four independent assay protocols, enabling quantitative analysis of four sample types: double-stranded DNA, single-stranded RNA, total protein, and fluorescent dyes.

For protein samples, simply perform the fluorescence incubation step using the provided kit; no additional lysis or dilution is required. After incubation, the samples can be directly loaded onto the instrument for analysis.

3: Multiple standard curves can be saved. After replacing the assay kit, is recalibration required?

The instrument features built-in local curve storage; factory‑predefined curves are permanently retained, and users can create, name, and retrieve multiple custom standard curves.

Operational Recommendations: When switching between brands or batches of fluorescent quantitative assay kits, it is recommended to re‑configure the standard curve to ensure assay accuracy.
4: How can the completed test data be exported, and can an editable experimental spreadsheet be generated directly?

The device is equipped with a standard USB port; simply plug in a standard USB flash drive to export all test records, which are saved in a universally compatible Excel format.

This device can store more than 1,000 complete sets of test data. For long-term, batch‑type experiments, data can be exported in segments, eliminating the need for manual transcription.

5: How long is the service life of a UV LED light source, and must the entire unit be replaced if the output value drifts?

Equipped with a long-life UV LED excitation source, it boasts a service life of tens of thousands of hours under typical laboratory operating conditions.

Precautions: When continuous drift or linear degradation occurs, only the light source module needs to be replaced, eliminating the need to replace the entire unit and reducing maintenance costs.
6: During the assay, will opening the cuvette cover expose operators to UV radiation?

The equipment is equipped with an automatic safety interlock that cuts off the UV light source when the cover is opened, causing the UV lamp to extinguish simultaneously upon opening.

The entire process emits no direct ultraviolet radiation, preventing eye and skin burns; single-person operation requires no additional protective eyewear.

7: Which tube specifications are compatible with the instrument, and can 1.5 mL centrifuge tubes be placed in the sample holder?

Compatible with 0.2 mL and 0.5 mL micro-volume PCR fluorescence‑specific assay tubes;

Restriction Notice: The cavity slot dimensions are compatible only with microcentrifuge tubes; 1.5 mL and larger centrifuge tubes cannot be accommodated, and forced insertion into the cavity is prohibited.
8: Do high- and low-concentration samples require serial dilutions, and how many orders of magnitude does the instrument’s linear detection range span?

The optical linear range spans five orders of magnitude, allowing most samples across a wide concentration range to be analyzed directly without gradient dilution.

Only when the sample concentration is completely outside the upper limit of the standard curve should it be diluted with the provided buffer and re‑measured.

9: What causes large discrepancies among repeated test results and elevated CV values, and how should this be addressed?

Common causes of failures and corresponding troubleshooting solutions:

1. Fluorescent dye residue adhering to the cavity’s light-transmitting window → Clean by wiping with a soft cloth dampened with purified water;

2. If the outer wall of the test tube is contaminated with liquid or fingerprints, wipe the wall dry before placing it in the slot.

3. Light source aging and degradation → Contact after-sales service to replace the LED light source module.

10: Can the TIQB0001 fluorometer be used for the analysis of clinical in vitro diagnostic samples?
Prohibited for use in the interpretation of clinical in vitro diagnostic tests!

This instrument is designated as a Research Use Only (RUO) device and does not possess medical device registration. It is intended solely for quantitative analysis of research samples in academic institutions, pharmaceutical companies, and disease control centers and is not suitable for use in clinical diagnostic assays.

Get a Quote


If you are interested in our products, please leave your email address, and we will contact you as soon as possible. Thank you!

Submit
Image Name

Order Consultation: Hu Manager

Image Name
Image Name

Order Consultation: An Manager

Image Name
Image Name

End-user Scientific Research Customer Order Consultation

Image Name
Image Name

Technical Consultation: Bai Technical

Image Name
Image Name

Customer Service

Image Name
Image Name

Douyin

Image Name
Image Name

WeChat Video Account

Image Name
Image Name

Kuaishou

Image Name

Contact Us

Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing  
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province 
WhatsApp: 86 18640171737

Leave a Message

If you are interested in our products, please leave your phone number.

Consult Now →

Product Subscription

Subscribe to us to stay informed about product updates and special offers

%{tishi_zhanwei}%

Copyright: Jianshi Biotechnology (Beijing) Co., Ltd.    Powered by:CEglobal

Business License

Product Inquiry

Filling in your phone number and email address will help us contact you promptly and resolve your questions as quickly as possible.