+
  • 吸头卡盒视频.mp4
  • 袋装吸头-通用.jpg

Pipette Tip Series (JSX Series)

Item number

Product Name

Packing specifications

Unit price

JSXL10 Series

Tip/filter cartridge/low adsorption/sterilized/extended 10 µL

1,000 pieces/bag; 20 bags/carton

Request for Quotation

JSXM10 Series

Tip bagged / filter cartridge / low adsorption / sterilized / 10 µL, 39 mm

1,000 pieces/bag; 20 bags/carton

Request for Quotation

JSXLL200 Series

Tip bagged / Filter cartridge / Low adsorption / Sterilized / Extended length, 200 µL

1,000 pieces/bag; 5 bags/box

Request for Quotation

JSXL200KY Series

Tip bagged / filter cartridge / low adsorption / sterilized / extended 200 µL, with graduations, yellow

1,000 pieces/bag; 20 bags/carton

Request for Quotation

JSX200KY Series

Tip bagged/with filter/low adsorption/sterile/200 µL, yellow, with graduations

1,000 pieces/bag; 20 bags/carton

Request for Quotation

JSX1000B Series

Tip bagged / filter cartridge / low adsorption / sterilized, 1000 µL, blue

1,000 pieces/bag; 5 bags/box

Request for Quotation

JSX1250B Series

Tip bagged / Filter cartridge / Low adsorption / Sterile / 1250 µL, blue

1,000 pieces/bag; 5 bags/box

Request for Quotation


Keywords



Product Description

FAQ

Product Information

Related Documents

Jianshi Bio Universal Bag-Style Pipette Tips – Full Range (including extended‑length, 39 mm, low‑adsorption, and filter‑tip models)

Product Overview

Covered with a standard bagged pipette tip from JianShi Bio. 39 mm 10 μL, 45.8 mm extended 10 μL, 52 mm standard 200 μL, 59.3 mm extended 200 μL, 89 mm extra‑extended 200 μL, 1000 μL, 1250 μL Seven core specifications, each available in standard, low‑adsorption (denoted by the suffix “D”), filter‑cartridge (suffix “F”), sterilized (suffix “S”), and multi‑attribute combination variants (such as FDS), to meet the needs of diverse experimental settings. The products are manufactured using… Imported PP material (compliant with USP Class VI standards) , in GMP Class 100,000 Cleanroom Manufactured to ensure the absence of DNases, RNases, pyrogens, endotoxins, and cytotoxicity; Standard size Compatible with mainstream pipettes on the market, Smooth inner wall Reduce liquid residue, High transparency Facilitates observation of the liquid level. Individually vacuum-sealed for on-demand use and to prevent contamination; intended for research use only (RUO) and not for clinical diagnostic purposes.

Product Features

  • Standard size with strong compatibility All specifications comply with industry‑standard dimensions, compatible with pipettes from brands such as Eppendorf, Thermo, and Gilson; extended‑length models—39 mm and 89 mm—are additionally suited for deep-well plates and containers of special depths.
  • Smooth inner wall for precise residue control. : The inner wall is polished to minimize liquid residue, and the low‑adsorption version (D) further reduces protein and nucleic acid adsorption, ensuring accurate dispensing with a pipetting accuracy error of ≤±2%.
  • High-quality raw materials, compliant and safe. : Imported PP material complies with USP Class VI medical-grade standards, exhibits stable physicochemical properties, does not leach harmful substances, and is compatible with a wide range of laboratory reagents.
  • High-Cleanliness Production Assurance : Produced in a GMP‑compliant Class 100,000 cleanroom; finished products are free of DNAase and RNAase. The filter‑cartridge version (F) prevents aerosol cross‑contamination, while the sterilized version (S) achieves a sterility level of Class 100.
  • Multiple security attributes : Through rigorous testing, it is free of pyrogens, endotoxins, and cytotoxicity, making it safe for use in sensitive applications such as cell culture and nucleic acid extraction.
  • High transparency for easy observation : High‑purity raw materials and excellent tip transparency; the 200 μL graduated version allows for intuitive reading of liquid volumes, minimizing operational errors.
  • Individually wrapped for convenient access. Vacuum‑sealed, individually packaged; easy to open without risk of contamination, and can be separated as needed for use, making it suitable for a variety of small‑quantity and batch‑processing applications in the laboratory.
  • Flexible length options for full coverage : Available in multiple lengths—39 mm, 45.8 mm, 52 mm, 59.3 mm, 89 mm, 87 mm, and 102 mm—compatible with a variety of containers, including shallow-well plates, deep-well plates, centrifuge tubes, reagent bottles, and more;
  • Full‑specification and multi‑attribute coverage: Includes seven core specifications, each available in standard, low‑adsorption, cartridge, sterilized, and combination variants; yellow and blue color options facilitate visual differentiation of capacity.
  • Scientific packaging optimized for batch use: standardized packaging of 1,000 tips per bag, with 20 bags per carton (for 10/200 µL small‑volume tips) or 5 bags per carton (for 1,000/1,250 µL large‑volume tips), meeting the needs of laboratory bulk procurement.
  • Color-coded for easy identification: the yellow 200 μL version and the blue 1000/1250 μL versions allow for quick differentiation of volume specifications, reducing the risk of selecting the wrong size.
  • Drop-resistant, durable, and low‑wear: The pipette tip features uniform wall thickness and exceptional toughness, resisting breakage and deformation during repeated pipetting, thereby reducing consumable replacement frequency and experimental costs.

Technical Specification Details for Universal Bagged Tips (All Sizes)

Specification Category Item number Product Name Packing specifications Product image
39mm 10μL JSXM10 Series 10 µL extended tip / filter element / low adsorption / sterilized 1,000 pieces/bag; 20 bags/carton
39mm
45.8mm 10μL JSXL10 Series 10 µL extended tip/filter/low adsorption/sterile 1,000 pieces/bag; 20 bags/carton
45.8mm
52mm 200μL JSX200KY Series 200 µL pipette tip/filter, low-binding, sterile, yellow, with graduations 1,000 pieces/bag; 20 bags/carton
52mm
59.3mm 200μL JSXL200KY Series 200 µL extended tip/filter, low-binding, sterile, with graduations, yellow 1,000 pieces/bag; 20 bags/carton
59.3mm
89mm 200μL JSXLL200 Series 200 µL extended tip / filter element / low adsorption / sterilized 1,000 pieces/bag; 5 bags/box
89mm
1000 μL JSX1000B Series 1000 µL pipette tip / filter cartridge / low adsorption / sterilized, blue 1,000 pieces/bag; 5 bags/box
87mm
1250 μL JSX1250B Series 1250 µL pipette tip / filter cartridge / low adsorption / sterilized / blue 1,000 pieces/bag; 5 bags/box
102mm

Jianshi Bio – Complete Range of Universal Bagged Pipette Tips

7 Common Specifications (including extended length, 39 mm, low‑adsorption, and filter‑cartridge models) – Frequently Asked Questions

Core specification coverage

  • 10 μL : Extended version (45.8 mm), 39 mm special edition
  • 200 μL : Standard model (52 mm), extra-long model (89 mm)
  • Large volume : 1000 μL (87 mm), 1250 μL (102 mm)
  • Special edition : With scale, yellow/blue identification version

Meaning of Product Code Suffixes

  • D : Low adsorption (reduces protein/nucleic acid adsorption)
  • F : Filter cartridge (prevents aerosol cross-contamination)
  • S : Sterilization (gamma-ray irradiation, Class 100 aseptic)
  • Y/B : Yellow/Blue (visual distinction capacity)

Packing specifications

  • Small volume (10/200 μL) : 1,000 pieces/bag, 20 bags/carton
  • Large capacity (1000/1250 μL) : 1,000 pieces/bag, 5 bags/box
  • Individually packaged : Sterilized version includes a separate sterile pouch
  • Compatible Scenarios : Conventional experiments, deep-well plates, aseptic techniques

High-Frequency FAQ for the Tip Series

1: What’s the difference between the 10 μL extended‑length model (JSXL10 series) and the 39 mm model (JSXM10 series), and how should I choose?

The key difference lies in length and intended applications: the extended version measures 45.8 mm, while the 39-mm version is 39 mm long; both are compatible with 10 µL pipettes, but they are suited to different types of containers.

1. Extended version (45.8 mm): Compatible with deep-well plates (e.g., 96‑well or 384‑well deep-well plates), enabling aspiration to the bottom of the wells and minimizing residual liquid.

2. 39 mm model: Compatible with standard centrifuge tubes, reagent bottles, and other shallow-depth containers; shorter in length for greater operational flexibility.

Selection Recommendations : For high-throughput experiments using deep-well plates, choose the extended-length version; for standard single-tube sampling, opt for the 39 mm version.
2: What do the D, F, and S suffixes in the product codes signify, and what are their respective application scenarios?

The suffix serves as an identifier for the pipette tip’s core functionality; different combinations correspond to distinct experimental requirements.

1. D (Low Adsorption) : The inner wall has been specially treated to minimize the adsorption of biomolecules such as proteins and nucleic acids, making it suitable for sample‑sensitive assays like ELISA and qPCR.

2. F (filter element) : The tip features a built-in filter that prevents aerosols from entering the pipette body, thereby minimizing cross-contamination; it is ideal for applications such as nucleic acid extraction and viral detection.

3. S (Sterilization) : Sterilized by gamma-ray irradiation, achieving a sterility level of 100, suitable for cell culture and sensitive experiments conducted within a sterile workbench.

Combination Example : JSXL10-FDS = 10 μL extended tip + filter + low-binding + sterilized, suitable for nucleic acid extraction in sterile environments.
3: Are the tips in this series compatible with mainstream pipette brands on the market? Do special specifications (such as extended‑length 200 μL tips) require dedicated pipettes?

All pipette tips in the series comply with the ISO universal size standard and are compatible with pipettes from leading brands such as Eppendorf, Thermo, Gilson, Bio-Rad, and Dalong—no special adapters required.

1. Standard specifications (200 μL, 1000 μL): Compatible with single-channel and multi-channel pipettes of the corresponding volume range;

2. Special specifications (extra‑long 200 μL, 39 mm 10 μL): These differ only in length; the interface dimensions are identical to the standard models, and the corresponding‑volume pipettes can still be used without the need to purchase additional specialized equipment.

4: What are the advantages of the low‑adsorption version (with the “D” suffix) compared to the standard version? Can the low‑adsorption version be used in routine experiments?

1. Core Advantages : The low‑adsorption model features a dual‑process inner wall treatment—hydrophilic coating plus polishing—resulting in liquid residue of ≤0.1 μL, compared to approximately 0.5 μL for the standard model, thereby delivering a more pronounced improvement in recovery rates for trace samples (e.g., 2 μL or less).

2. Applicable Scenarios : Recommended for experiments with small sample sizes and low concentrations (e.g., single-cell PCR, rare‑target nucleic acid detection);

3. General experimental compatibility : For routine experiments—such as aliquoting standard reagents or pipetting large volumes—low‑adsorption tips may be used; however, they are slightly more expensive. From a cost‑effectiveness standpoint, it is recommended to select based on specific needs.

Attention : Low‑adsorption models cannot be sterilized at high temperatures (as this will damage the coating). For reusable items, rinse with enzyme‑free water to prevent detergent residue.
5: Can the filter element of the cartridge‑type model (with the “F” suffix) be reused? How long does its protection against aerosol contamination last?

1. How to Use the Filter Cartridge The filter cartridge is designed for single use and should be discarded after each sampling; it must not be disassembled or reused, as reuse may cause blockage or contamination.

2. Pollution prevention effect The filter element can capture aerosol particles ≥0.2 μm; as long as the pipette tip remains intact during the experiment, its anti-contamination performance persists until the tip is discarded.

3. Applicable Scenarios : Particularly well suited for handling high-concentration samples (such as virus-positive specimens), it effectively prevents contamination of the pipette body and avoids cross-contamination in downstream experiments.

6: What is the sterile shelf life of the sterilized version (S‑suffix)? How should unused pipette tips be stored after opening?

When unopened, the sterile shelf life is 24 months (subject to the manufacturing date indicated on the packaging); once opened, it must be stored strictly in accordance with aseptic procedures.

1. Store after opening. : The package must be opened inside a laminar flow hood. Any remaining pipette tips should be returned to their original packaging, sealed, and stored in a clean, dry, light‑protected environment to prevent moisture or dust contamination.

2. Usage period : After opening, it is recommended to use the product within one month. If this time limit is exceeded, re-sterilization is required (only PP material can withstand 121°C autoclaving; after sterilization, the “sterile” label becomes invalid, but the product may still be used for non‑sterile experiments).

7: Are the yellow model (e.g., JSX300KY) and the blue model (e.g., JSX1000B) different only in color, or do they have any other functional differences?

The core functionality of the colored version is identical to that of the transparent version with the same specifications; it only adds a “visual differentiation” feature, with no other performance differences.

1. Yellow style : Primarily designed for 200 μL/300 μL tips (e.g., JSX300KY, JSX200KY), enabling quick identification of medium-capacity pipette tips during experiments.

2. Blue style : Primarily intended for large-volume tips of 1000 μL/1250 μL (e.g., JSX1000B, JSX1250B) to prevent confusion with medium-capacity tips.

Advantageous Scenarios : When using pipette tips of multiple volumes simultaneously (e.g., performing 200 μL aliquoting and 1,000 μL transfers at the same time), color coding can help reduce the likelihood of selecting the wrong tip.
8: Why are small-volume tips (10/200 μL) packaged 20 per box, while large-volume tips (1000/1250 μL) are packaged 5 per box?

Packing specifications are designed based on “usage frequency + weight per bag,” balancing convenience with transportation costs:

1. Small-volume pipette tip : The laboratory has a high usage frequency (e.g., 200 μL for routine pipetting); 20 pouches per box (totaling 20,000 tips) can meet long-term needs, reducing the frequency of reorders.

2. Large-capacity pipette tip : Each tip is heavier (approximately 0.8 g per 1000 μL tip), and the box contains 5 bags, totaling 5,000 tips, which helps keep the overall box weight within a manageable range (about 4 kg), facilitating handling while also preventing tip deformation from prolonged storage.

9: Does the tip length (e.g., a 200 μL tip that’s 89 mm long) affect pipetting accuracy? Can short tips be used for sampling in deep-well plates?

1. The Relationship Between Length and Precision : The tip length does not affect pipetting accuracy (which is determined by the pipette and the smoothness of the tip’s inner wall); it only influences the sampling depth.

2. Limitations of the short-suction nozzle : Short pipette tips (e.g., the standard 200 μL type, 52 mm) cannot reach the bottom of deep-well containers (such as 50 mL centrifuge tubes or deep-well plates), leading to liquid residue and compromising sample recovery rates.

3. Advantages of the long suction nozzle : The extended-length version (e.g., 89 mm) can reach the bottom of deep containers, making it ideal for aspirating viscous liquids or small residual volumes, thereby minimizing waste.

Attention : When using long pipette tips, ensure that the pipette’s stroke is sufficient to prevent the tip from failing to aspirate liquid completely (e.g., using a 100 μL pipette with an 89 mm‑long tip may result in inaccurate volumes due to insufficient stroke).
10: How should unopened pipette tips be stored? Will long-term storage degrade their performance?

Unopened pipette tips should be stored at room temperature (10°C–30°C), in a dry environment (relative humidity ≤60%), and protected from light, avoiding high temperatures, high humidity, or direct sunlight.

1. Performance influencing factors : High temperatures (>40°C) can cause PP material to soften, compromising the tip’s seal; high humidity can lead to moisture on the inner wall of the tip, potentially fostering microbial growth (for non-sterile models).

2. Long-term storage recommendations : Within the shelf life (24 months unopened), provided storage conditions are compliant, the pipette tips will maintain their smoothness, seal integrity, and other performance characteristics. After the expiration date, we recommend performing a precision test first—such as weighing after dispensing—and using only if the results meet the required standards.

Special Attention : Low-adsorption version (D suffix) – Avoid prolonged contact with organic solvents such as ethanol and methanol, as this may damage the low-adsorption coating.

Get a Quote


If you are interested in our products, please leave your email address, and we will contact you as soon as possible. Thank you!

Submit
Image Name

Order Consultation: Hu Manager

Image Name
Image Name

Order Consultation: An Manager

Image Name
Image Name

End-user Scientific Research Customer Order Consultation

Image Name
Image Name

Technical Consultation: Bai Technical

Image Name
Image Name

Customer Service

Image Name
Image Name

Douyin

Image Name
Image Name

WeChat Video Account

Image Name
Image Name

Kuaishou

Image Name

Contact Us

Jianshi Biotechnology (Beijing) Co., Ltd.
Company Address: Room 401, Building 11, No. 12 Courtyard, Juyuan Middle Road, Mapo Town, Shunyi District, Beijing  
Phone: 86 18640171737
E-mail: gwang@jianshibio.com
Jianshi Biotechnology (Zhejiang) Co., Ltd.
Address: Building 11, No. 36 Xingshun Road, Zhongyi Ningbo Eco-park, Yuyao City, Zhejiang Province 
WhatsApp: 86 18640171737

Leave a Message

If you are interested in our products, please leave your phone number.

Consult Now →

Product Subscription

Subscribe to us to stay informed about product updates and special offers

%{tishi_zhanwei}%

Copyright: Jianshi Biotechnology (Beijing) Co., Ltd.    Powered by:CEglobal

Business License

Product Inquiry

Filling in your phone number and email address will help us contact you promptly and resolve your questions as quickly as possible.